| StorageTek
Main
StorageTekT TimberWolf® 9730 tape library

| The
StorageTekT TimberWolf® 9730 tape library is a compact,
entry-level SCSI-based, desktop or rack-mountable
DLT library for Windows NT and Unix users with distributed
data.
- Continuously available. Constantly
monitors drive status for automatic error detection
and recovery. Spontaneously resumes normal operations
after a power failure. Uses self-calibration and
requires no scheduled maintenance.
- Flexible and scalable. Configure
with one or two DLT drives and 18 cells; or three
or four DLT drives and up to 30 cells.
- Advanced rotational robotics.
Accurate, high-speed rotational robotics enable
fast cartridge exchanges, high-cartridge volume
and easy access.
- Keen vision system. Camera-based
vision system has no moving parts and is more accurate
than standard bar code readers.
- Easily integrated. The library
integrates with UNIX, Windows NT and Novell NetWare.
Works well with all hardware, making the platform
transparent to users.
- Small footprint. Store up to 2.1
TB (compressed) of information in a workstation-size
unit.
|
|
| 9730 Specifications
|
| Functional Data |
Number
of Cartridge Slots |
18 or 30
(28 with four drives) |
|
Number
of Drives |
Up to four
DLT 4000 or DLT 7000 drives |
|
| |
Library
Capacity
(30 slots) |
Uncompressed |
Compressed (2:1) |
DLT 4000
(20 GB cartridges) |
600 GB |
1.2 TB |
DLT 7000
(35 GB cartridges) |
1.05 TB |
2.1 TB |
| |
Library
Throughput
(4 drives) |
Uncompressed |
Compressed (2:1) |
DLT 4000 |
21.6 GB/hr |
43.2 GB/hr |
DLT 7000 |
72 G/hr |
144 GB/hr |
|
| |
Media |
DLT Tape
IV |
|
Average
Cartridge Access Time |
6 seconds |
|
Audit Time |
< 1
minute |
|
Robotics
Control |
SCSI-2
media changer command set, Fast/Wide interface, single-ended
or differential (selectable in field) |
|
Bar Code
Reader |
Standard,
camera-based vision system |
|
Calibration |
Automatic
(cells, drives and cartridge access port) |
|
Drive Cleaning |
Automatic,
library or software initiated |
|
Cartridge
Access Port |
Standard,
single-cartridge capacity |
|
Control
Panel |
User-friendly
configuration and diagnostic controls, status display
and viewing window |
|
Serviceability |
In-rack
service; key components are customer-serviceable;
hot swappable drives; RS-232C port for diagnostics
and software upgrades |
|
| |
| Reliability |
MEBF
(Mean Exchanges Between Failures) |
1,000,000 |
|
MTBF
(Mean Time Between Failures) |
70,000
hrs. (full operation) |
|
MTTR
(Mean Time To Repair) |
Less than
30 min. |
|
| |
| Physical Data |
| Width |
19 in. (48.3 cm) |
| |
| Height |
17.5 in. (44.5 cm) |
| |
| Depth |
28.6 in. (72.6 cm) |
| |
| Weight |
110 lbs. (49 kg) |
|
| |
| Environmental Specifications |
Temperature |
| |
Operating |
Storage |
Transit |
| °F |
+59 to +90 |
+50
to +104 |
-40 to +140 |
| °C |
+15 to +32 |
+10 to +40 |
-40 to +60 |
| |
|
Humidity
Wet bulb
(Max., non-condensing) |
| |
20% to 80% |
10% to 95% |
10% to 95% |
| °F |
+85 |
+95 |
+95 |
| °C |
+35 |
+35 |
+35 |
| |
|
Altitude |
| Ft |
-250 to +10000 |
-250
to +10000 |
-250 to +10000 |
| M |
-76 to 3050 |
-76 to 3050 |
-76 to 3050 |
|
|
| |
| Power Source |
Power Input |
100 - 127
VAC @ 60 Hz single phase |
|
Power Input |
200 - 240
VAC @ 50 Hz single phase |
|
Power Consumption
(max)
Library |
2.0A @
120V, 1.0A @ 240V, 820 BTU/hr. |
|
DLT 4000
(each) |
0.8A @
120V, 0.42A @ 240V, 342 BTU/hr. |
|
DLT 7000
(each) |
0.92A @
120V, 0.46A @ 240V, 375 BTU/hr. |
|
| |
| Safety and Emissions |
Safety |
CSA standard
CAN/CSA-C22.2 no. 950-M93
UL standard 1950, Third Edition; EN60950 |
|
Emissions |
FCC #47,
Part 15, Subpart B, Class A; VCCI Class A
European Union CE emissions standards
AS/NZS 3548:1995 (Australia, N.Z.); ICES-003 (Canada) |
|
Immunity |
European
Union CE immunity standards
AS/NZS 4252.1:1994 Generic Immunity Standard |
|
Please contact us for stock availability,
sales prices and fixed repair prices.
Contact
UK
 |